60W Dual Output Ngalih Power Supply seri D-60
Efisiensi dhuwur, linuwih dhuwur
Input AC universal / lengkap
100% tes burn-in beban penuh
Proteksi: Sirkuit cendhak / Overload / Overvoltage
Indikator LED kanggo daya
Pendinginan kanthi konveksi udara bebas
Frekuensi ngoper tetep ing 54KHz
garansi 2 taun
SPESIFIKASI | ||||||
OUTPUT | ||||||
Model | D-60A | D-60B | D-60C | |||
Nomer output | CH1 | CH2 | CH1 | CH2 | CH1 | CH2 |
Tegangan DC | 5V | 12V | 5V | 24V | 15V | -15V |
Rated Saiki | 4A | 3A | 2A | 2A | 2A | 1.5A |
Range Saiki | 0.8-4A | 0.3-3A | 0.8-3A | 0.2-2A | 0.5-2A | 0.2-1.5A |
Daya Rated | 56W | 58W | 60W | |||
Ripple & Noise | 80mVp-p | 100mVp-p | 80mVp-p | 120mVp-p | 100mVp-p | 120mVp-p |
Tegangan Adj.Range | CH1: -5%+10% | CH1: -5%+10% | CH1: -5%+10% | |||
Toleransi Tegangan | ± 2% | ± 6% | ± 3% | ± 5% | ± 3% | ± 5% |
Setup, Munggah, Tahan Wektu | 800ms, 50ms, 10ms/115VAC 300ms,50ms,80ms/230VAC ing beban penuh | |||||
INPUT | ||||||
Range Tegangan | 85~132VAC/170~264VAC dipilih dening ngalih 47~63Hz;240 ~ 370VDC | |||||
Arus AC | 1.8A / 115V 0.9A / 230V | |||||
Efisiensi | 74% | 76% | 78% | |||
Arus Inrush | wiwitan kadhemen 25A / 115V 50A / 230V | |||||
Arus bocor | <1mA/240VAC | |||||
pangayoman | ||||||
Over Load | 105% ~ 150% daya output dirating | |||||
Jinis pangayoman: Mateni voltase o/p, pulih kanthi otomatis sawise kondisi fault dibusak | ||||||
Swara Tegangan | CH1: 115%~135% | |||||
Jinis pangayoman: mode hiccup, pulih otomatis sawise kondisi fault dibusak | ||||||
LINGKUNGAN | ||||||
Suhu kerja, Kelembapan | -10 ℃ ~ + 60 ℃;20% ~ 90% RH | |||||
Suhu panyimpenan, Kelembapan | -20 ℃ ~ + 85 ℃;10% ~ 95% RH non-kondensasi | |||||
Temp.Koefisien | ± 0,03% / ℃ (0 ~ 50 ℃) | |||||
Getaran | 10~500Hz, 2G 10min./1siklus, periode 60menit, saben sumbu X, Y, Z | |||||
KESELAMATAN | ||||||
Tahan Tegangan | I/PO/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||
Ketahanan Isolasi | I/PO/P, I/P-FG, O/P-FG: 100M Ohm/500VDC | |||||
STANDAR | ||||||
Standar Keamanan | Desain deleng UL1012, UL60950, EN60950 | |||||
Standar EMC | Desain deleng EN55022(CLSPR22),EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11;ENV50204, EN55024 | |||||
LAIN | ||||||
ukuran | 159 * 97 * 38mm (L * W * H) | |||||
Bobot | 0,55 Kg | |||||
Packing | 45pcs / 25.5Kg / 1.45CUFT | |||||
CATETAN | ||||||
1.Kabeh paramèter sing ora disebutake khusus diukur ing input 230VAC, beban dirating lan 25 ℃ suhu sekitar. | ||||||
2. Ripple & gangguan diukur ing bandwidth 20MHz kanthi nggunakake kabel pasangan bengkong 12" sing diakhiri karo kapasitor paralel 0.1μf & 47μf. | ||||||
3.Toleransi: kalebu nyetel toleransi, angger baris lan angger-angger mbukak. | ||||||
4.Sumber daya dianggep komponen kang bakal diinstal menyang peralatan final.Peralatan pungkasan kudu dikonfirmasi maneh yen isih tundhuk karo arahan EMC. |